What was found
PDX - C1 - RT INBD SEAT RAIL AT APPROX STA 35 TO 37.5 HAS LIGHT SURFACE CORROSION ON THE TOP SURFACE. BLENDED OUT CORROSION IAW RD 8/4-53-2358 GENERAL NOTES 1,3-5. MEASURED BLENDED AREA AND FOUND LESS THE .045 INCH MATERIAL REMOVED, REMAINING THICKNESS IS .415 INCH. BLENDED AREA FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2358. HFEC IAW NDTM PART 6 51-00-01 AND RD 8/4-53-2358 GENERAL NOTES 2. NO CRACKS NOTED. APPLIED FASTWELD EPOXY IAW RD 8/4-53-2358 GEN NOTE 6.