What was found
PDX - C5 - THE LT INBOARD SEAT TRACK NR 7 AT STA X375 HAS APPROX 4 INCHES OF CORROSION ON THE INBOARD FLANGE. REMOVED CORROSION FROM AFFECTED AREA BY BLENDING IAW RD8/4-53-884 PAGE 6, GENERAL NOTES 1, 3, 5. MINIMUM REMAINING THICKNESS OF SEAT TRACK FLANGE IN AREA OF BLEND IS .082 INCH BLEND IS WITHIN LIMITS PER RD8/4-53-884. ALODINED BLENDED SURFACES IAW RD8/4-53-884, PAGE 6 GENERAL NOTES NR 6. PERFORMED HFEC INSPECTION OF BLEND IAW 1-84-7A, PT 6, 51-00-02, NO CRACKS NOTED. EPOXY PRIMED AND TOP COATED BLENDED AREA IAW RD 8/4-53-884, PAGE 6, GEN NOTES 7, 8.