What was found
PDX - C5 - NR 5 SEAT TRACK HAS LITE SURFACE CORROSION ON THE INBOARD FLOORBOARD SUPPORT FLANGE. NR 5 SEAT TRACK HAS CORROSION RIGHT UP TO FASTENERS AND FOUND TO BE OUT OF LIMITS REF RD 8/4-53-884, NOTES ON PAGE 2. BLENDED AREA OF CORROSION TO REMOVE DAMAGE IAW RD 8/4-53-884 AND REMOVED RIVETS IN FLANGE IN THE AREA OF THE BLEND TO EVALUATE THE CONDITION OF FASTENER HOLES. HFEC IAW -8 400 NDTM PART 6 51-00-01. NO CRACKS NOTED. UT THICKNESS IAW -8 400 NDTM PART 1 51-00-04 HI .080 INCH LO .063 INCH. MAPPED FOR ENGINEERING. HFEC IAW -8 400 NDTM PART 6 51-00-01 AROUND FASTENER HOLES. NO CRACKS NOTED.