What was found
PDX - MOD - EXTERIOR SKIN IS CHAFED 1 INCH LONG WITH DENT ADJACENT TO IT AT FS 980 AND 6 O`CLOCK, CAUSED BY CONTACT WITH PANELS 195DL AND 196DR. BLENDED SMALL CHAFE MARK TO REMOVE DAMAGE FROM SCREW CONTACTING SKIN. FOUND AREA TO BE OUT OF LIMITS IAW SRM 53-61-01-101-003-A01 DUE TO DENTED AREA. CHAFED AREA IS STILL DAMAGED ALONG THE FASTENER LINE. HFEC INSPECTED DENT AND CHAFED AREA FOR CRACKS IAW CRJ 700 NDTM PT 6, 53-00-000-250-A01. NO CRACKS NOTED. UT THICKNESS CHECK OF CHAFE AND DENT AREA IAW CRJ 700 NDTM PT 1, 51-20-004. CHAFE HIGH; .112 LOW; .109. DENT HIGH; .106 LOW; .064. BLENDED REMAINING DAMAGE ALONG FASTENER LINE. HFEC INSPECTED BLENDED AREA FOR CHAFE IAW CRJ 700 NDTM PT 6, 53-00-000-250-A01. NO CRACKS NOTED. UT THICKNESS CHECK IAW CRJ 700 NDTM PART1, 51-20-04. HIGH .112 LOW .069. REMOVED THREE HI LITES IN AREA OF BLEND, MAPPED FOR ENGINEERING. REMOVED FASTENERS AND CUT OUT DAMAGE IAW REO670-53-61-498/3. HFEC IAW CRJ700 NDTM PT 1, 51-20-006 AT CUTOUT, NO CRACKS NOTED. FABRICATED NEW DOUBLERS AND FILLERS IAW REO 670-53-61-498/3. FABRICATED SHIMS, APPLIED ETCH AND ALODINE AND PRIMER TO ALL PIECES IAW REO670-53-61-498/3 NOTES 3, 6-8,11 AND 17. INSTALLED REPAIR IAW REO670-53-61-498/3 WITH FILLER, DOUBLERS AND SHIM. FILLET SEALED DOUBLER, PRIMED AND PAINTED AREA.