What was found
PDX - 8 YR TASK - FWD SERVICE DOOR APERTURE HAS LITE SURFACE CORROSION AROUND THE BASE OF THE LOWER FWD DOOR STOP FITTING AT APPROX FS 325.00 STR 18R. REMOVED LWR FWD DOOR STOP FITTING FOR ACCESS TO CORROSION. REMOVED LOWER SILL ANGLE TO GAIN ACESS TO CORROSION AND REMOVED CORROSION IAW SRM 53-21-23. HFEC IAW CRJ 700 NDTM PART 1, 51-20-006, NO CRACKS NOTED. UT THICKNESS IAW CRJ 700 NDTM PART 1, 51-20-004, HIGH .063 LOW .056. INSPECTED AREA OF BLEND AND FOUND BLEND TO BE OUTSIDE ALLOWABLE LIMITS IAW SRM 53-21-23 WITH .007, REMOVED AND IS BEYOND 10 PERCENT OF THE ORIGINAL THICKNESS. MAPPED FOR ENGINEERING. ALODINED, PRIMED, AND PAINTED REWORKED AREA IAW REO 670-53-21-485 DISPOSITION STEP 3. INSTALLED LOWER SILL ANGLE TO AIRCRAFT STRUCTURE WITH SOLID RIVETS IAW CRJ 700 SRM 51-42-06. COMPLETED REO 670-53-21-485 BY APPLYING CORROSION INHIBITING COMPOUND TO AFFECTED AREA. INSTALLED LOWER FWD DOOR STOP WITH ORIGINAL HARDWARE, COMPLIED WITH ADJUSTMENT IAW CRJ 700 AMM 52-41-00-82-801-A01 1-4A(18). AREA OF BLEND FOUND WITHIN LIMITS IAW REO 670-53-21-485, COMPLETED ADJUSTMENTS IAW CRJ 700 AMM TASK 52-41-00-820-801 PARA 4A(19)-5D.