What was found
DURING INSPECTION FOUND CHAFING ON FLAP INNER SURFACE UNDER INBD FLAP NR 3 VANE ACTUATOR, . BLENDED GOUGE. BLEND MEETS THE CRITERIA STATED IN THE SRM 57-52-01-001-A01 ALLOWABLE DAMAGE LIMITS PG 102. WORK DONE IAW SRM 51-21-11, 51-25-06 AND 51-42-06.