As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND LIGHT CORROSION AT LOWER FS 501.00 BETWEEN S21L AND S22L. REMOVED AFFECTED SOLID RIVETS TO ACCESS CORROSION ON WEB FLANGE. BLENDED .002 MATERIAL FROM FLANGE WITH A MAXIMUM BLEND OF .005 ALLOWED, REMOVING ALL CORROSION ON FLANGE. ALL WORK DONE IAW SRM 51-40-06 AND 51-21-06.