As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT INBD FLAP VANE CHAFED ON TOP TRAILING EDGE. BLENDED CHAFE AT RT INBD FLAP VANE AT TOP OF TRAILING EDGE. FLAP VANE TOP T/E IS .050", BLENDED AREA OUT .002", REMAINING THICKNESS IS .048". BLENDED AREA WITHIN LIMITS OF SRM 57-52-02. ALL WORK DONE IAW SRM 51-21-11, 51-25-06, AND 51-25-00.