As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSP FOUND CORROSION AT INTERSECTION OF STR 19LT AND FS 295.00. REMOVED RIVET AT CLEAT S19LT AND FS 295.00 IAW SRM 51-42-06.BLENDED .003" OF MATERIAL THICKNESS AT .050". WITHIN LIMITS IAW SRM 51-21-06 AND 53-00-00. TREATED, PRIMED AND PAINTED IAW SRM 51-21-11, 51-25-06 AND 51-25-21. INSTALLED RIVET IAW SRM 51-42-21.