What was found
CORROSION FOUND ALONG DOOR FRAME OF AVIONICS DOOR (FWD) BETWEEN FS349 AND FS 364 NEXT TO STR 27R. REMOVED 6 RIVETS FROM AREA FOR ACCESS IAW SRM 51-42-06. REMOVED CORROSION IAW SRM 51-21-06. MAX MATERIAL REMOVED .007", WITHIN LIMITS IAW SRM 53-21-23. TREATED, PRIMED, AND PAINTED IAW SRM 51-21-11, 51-25-06 AND 51-25-16. INSTALLED RIVETS ALONG INTERCOSTAL IAW SRM 51-42-06. PERFORMED LPI, NO DEFECTS NOTED IAW REO 670-53-21-496. INSTALLED RIVETS AT FS 364.00, TREATED, PRIMED, PAINTED IAW SRM 51-42-06, 51-21-11, 51-25-06 AND 51-25-16.