What was found
DURING INSP FOUND TOOLING DAMAGE OF FS 597 FRAME ATTACH FLANGE BETWEEN STR 23R AND 22R. REMOVED RIVETS FOR FOM, BLENDED OUT TOOLING MARKS AND PERFORMED LPI IAW SRM 51-42-06, 51-21-06 AND NDTM 51-20-006. TREATED, PRIMED, INSTALLED RIVETS AND PAINTED WORKED AREA IAW SRM 51-21-11, 51-25-06, 51-42-06 AND 51-25-16.