What was found
EVIDENCE OF CORROSION ON STR 26R ATTACHING FLANGE BETWEEN FS 295 - FS 310 IN AVIONICS BAY. REMOVED RIVETS FOR ACCESS IAW SRM 51-42-06. BLENDED OUT CORROSION IAW SRM 51-21-06. PERFORMED LPI ON STR, NO CORROSION FOUND AT THIS TIME IAW NDTM LPI 51-20-006. FOUND CORROSION TO BE BEYOND LIMITS IAW REO 670-53-21-503. REMOVED DAMAGED STRINGER SECTION. PERFORMED LPI ON CUT LINES, NO CRACKS NOTED AT THIS TIME, REO 670-53-21-503, NDTM LPI 51-20-006. CUT STR SPLICE, TREATED, PRIMED IAW SRM 51-24-36-001-001-A01, 51-21-11-001-001-A01, AND 51-25-06-001-001-A01. FABRICATED REPAIR FILLER AND DOUBLER IAW SRM 53-00-03 REPAIR -001-A01, PRIMED AND TREATED ALL AREAS. INSTALLED FILLER AND DOUBLER PAINTED AND APPLIED AV8 IAW 51-42-21-001-001-A01, REO 670-53-21-503, 51-25-16-001-001-A01 AND 51-21-11-001-001-A01.