What was found
EVIDENCE OF CORROSION ON STR 26R DOUBLER ATTACHING FLANGE AND WEBBING AT FS 333. REMOVED RIVETS FOR ACCESS, BLENDED CORROSION IAW SRM 51-21-06. PERFORMED LPI ON STR, NO CORROSION FOUND DAMAGE FOUND TO BE WITHIN LIMITS IAW LPI NDTM 51-20-006 AND REO 670-53-21-503. TREATED, PRIMED IAW SRM 51-21-11 AND 51-25-06. INSTALLED FASTENERS IAW SRM 51-42-06, 51-42-21, PAINTED REPAIR IAW SRM 51-25-16.