What was found
EVIDENCE OF CORROSION ON STR 24R DOUBLER ATTACHING FLANGE AND WEBBING JUST FWD OF FS 333 IN AVIONICS BAY. REMOVED FASTENERS FOR ACCESS, BLENDED CORROSION IAW SRM 51-21-06. PERFORMED LPI ON STR, NO CORROSION FOUND, DAMAGE FOUND TO BE WITHIN LIMITS IAW NDTM 51-20-006 AND REO 670-53-21-503. TREATED, PRIMED AND INSTALLED FASTENERS AS REQUIRED IAW SRM 51-21-11, 51-25-06 AND 51-42-06. APPLIED TOP COAT IAW SRM 51-25-16.