As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND CORROSION ON SUPPORT ANGLE FOR FLOOR PANEL 141AL AT FS 280. REMOVED FLOOR PANEL SUPPORT ANGLE AT FS 280 FRAME IAW SRM 51-42-06. LOCATED FASTENER HOLES IN NEW SUPPORT ANGLE IAW SRM 51-42-06, ALODINE, PRIMED AND PAINTED IAW SRM 61-21-11. INSTALLED NEW SUPPORT ANGLE AT FS 280 IAW SRM 51-42-06.