What was found
CORROSION FOUND ON FS 295.00 ATTACH FLANGE STR 27 - STR 26R. REMOVED RIVETS TO ALLOW ACCESS TO CORROSION IAW SRM 51-42-06. BLENDED .003 DEEP 2.5 INCH LONG BY .5 INCH WIDE. REMAINING MATERIAL .047 INCH OUT OF TOTAL THICKNESS OF .050. BLEND IS WITHIN LIMITS PER SRM 53-12-06. TREATED, PRIMED AND PAINTED IAW SRM 51-21-11, 51-25-06 AND 51-25-16.