As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C CHECK - DENT FOUND UNDER LT ICE SHIELD AT STA 264 BELOW STR 11L. MAPPED FOR ENGINEERING. PERFORMED HFEC OF DENTED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01. NO CRACKS NOTED. CUT OUT DAMAGE UNDER STR 11P AND 12P BETWEEN X258.5 AND X301 IAW RD 8/4-53-2913/3. HFEC IAW NDTM PART 6, 51-00-01 AND RD 8/4-53-3913/3 AT CUTOUTS, NO CRACKS NOTED. COMPLETED REPAIR IAW RD 8/4-53-2913/3.