As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CHAFE BELOW AFT POTABLE WATER FILL PORT FUSELAGE SKIN. BLENDED IAW SRM 51-12-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-51-01-003-A01. PERFORMED LPI IAW REO 670-53-51-042, NO DEFECTS NOTED. TREATED, PRIMED AND PAINTED IAW SRM 51-25-01-001-001-A01. ALL WORK DONE IN CONFORMITY WITH REO 670-53-51-042.