As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ATTEMPTED TO START APU, APU AUTO SHUTDOWN. RAMP REPORTED ALOT OF SMOKE. PLACED ON MEL 49-00-1. RETURNED TO SERVICE. MEL CLOSED ON 11-18-09. INTERROGATED CDS, FOUND CODE 102-3 ( UNDERSPEED) REMOVED AND REPLACED MAIN FUEL SOLENOID VALVE IAW AMM TASK 49-30-07-000-801 AND 49-30-07-400-801 C/W OP TEST OF APU IAW 49-00-00-710-801 OP CHECKS GOOD- (NOTE: TURBINE ROTATED FREELY NO TURBINE DRAG) C/W 3 START ATTEMPTS. ALL CHECKED GOOD. NO CURRENT FAULTS IN CDS. RETURNED TO SERVICE.