What was found
CORROSION FOUND AT FS 319.-333 S24R. BLENDED OUT CORROSION AND FOUND BLENDS TO BE IN A NO DAMAGE ALLOWED AREA. SENT TO MFG FOR REO. PERFORMED ECI ON STR 24R, NO CRACKS FOUND IAW NDTM 51-20-006. PERFORMED LPI ON CUTLINE ON NEW S24R, IAW NDTM 51-20-008. INSTALLED STRINGER 24R AND COMPLETED REPAIR IAW REO 670-53-21-514. TOPCOATED AND APPLIED CORROSION INHIBITING COMPOUND IAW 51-25-00-001-001-A01 AND 51-21-11-001-001-A01.