What was found
C-CHECK - SUSPECTED CORROSION ON SKIN JOINT AROUND RIVET AT APPROX ST 269.75 BETWEEN STR 31L AND 32L. DRILLED OUT RIVET AT SUSPECTED LOCATION AND REMOVED LESS THAN .001 OR CORROSION FROM AROUND FASTENER HOLE IAW SRM 51-42-05, 51-14-00 FOUND TO BE WITHIN LIMITS. HFEC INSP BLENDED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801. NO CRACKS NOTED. ALODINED, PRIMED AND INSTALLED SOLID RIVET IAW SRM 51-42-05 AND 51-25-10.