What was found
PDX - C5 CHECK - CORROSION ON FRAME FLANGE AT ST 341.00 BETWEEN STR 31L AND STR 32L. REMOVED RIVET FOR ACCESS AND BLENDED AREA OF CORROSION, FOUND BLEND AREA TO BE WITHIN LIMITS IAW RD 8/4-53-2344. PERFORMED HFEC INSP IAW 1-84-7A, PT 6, 51-00-01, NO CRACKS NOTED. PERFORMED THICKNESS CHECK IAW 1-84-7A, PT 1, 51-00-04 MAX, .050, MIN READ .054, .004 MATERIAL REMOVED. BLENDED AREA FOUND WITHIN LIMITS IAW RD8/4-53-2344. INSTALLED RIVET REF SRM 51-42-05 AND ALODINED, PRIMED AND PAINTED THE BARE METAL IAW RD 8/4-53-2344 GENERAL NOTES STEPS 4-6.