What was found
C5 CHECK - LT INBD FLAP UPPER SURFACE HAS LIGHT CHAFE DAMAGE AT APPROX STA YW 161.0 AND 20" FWD OF T/E. BLENDED TO REMOVE DAMAGE. HFEC INSP BLENDED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01-0250-801, NO CRACKS NOTED. UT THICKNESS CHECKED BLEND AREA IAW NDTM PART 1, 51-00-04, FOUND OUT OF LIMITS IAW SRM 57-51-30 PG 102. MAPPED FOR ENGINEERING. INSPECTED AREA OF BLEND AND FOUND IT TO BE WITHIN LIMITS IAW RD 8/4-57-1295. ALODINED, PRIMED AND PAINTED BARE AREA IAW RD 8/4-57-1295.