What was found
C-CHECK - CHAFING ON BOTTOM RT WING BOX WHERE TOP OF PANEL 264AR INTERSECT. BLENDED CHAFE ON BOTTOM RT WING BOX TO REMOVE ALL DAMAGE IAW SRM 57-11-30 (1-6)(B)(1-10). HFEC INSP BLEND FOR CRACKS IAW NDTM PART 6 51-00-01-250-801, NO CRACKS NOTED. UT THICKNESS CHECK IAW NDTM PART 1, 51-00-04, HIGH .280 LOW .241. FOUND TO BE OUT OF LIMITS IAW SRM 57-10-30, MAPPED FOR ENGINEERING. INSPECTED BLENDED AREA AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-57-1339. ROTO PEENED BLENDED AREA PER 8/4-52-1339. APPLIED SURFACE COATING IAW RD 8/4-52-1339.