What was found
CORROSION ON STRINGER 25R BETWEEN FS 333.00 AND 319.00. BLENDED AREA IS NO DAMAGE AREA YAW SUM 53-21-03-101-002-A01. MATERIAL REMAINING ON STIR IS .046 AND .060 ON DOUBLERS. SENT DAMAGE REPORT TO MFG FOR AN REO. PERFORM EKE ON BLENDED AREA, NO CRACKS FOUND AT THIS TIME, YAW NET 51-20-006. TREATED, PRIMED AND PAINTED YAW SUM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. APPLIED AV-8 YAW SUM 51-21-11-001-001-A01. WORK PERFORMED IS IN CONFORMITY WITH TASK CARD REO 670-53-21-533.