What was found
RFD - C CHECK - LT OTBD FLAP VANE ATTACH FITTINGS ARE DAMAGED. DAMAGE WAS FOUND TO BE IN LIMITS FOR ATTACH FITTING/BUTE DOOR CAM AT FS 296.07 IAW SRM 57-53-01-101-001-A01. ALLOWED TO HAVE A REMAINING MATERIAL THICKNESS OF .030. CURRENT MATERIAL THICKNESS IS AT .035. DAMAGE WAS FOUND TO BE IN LIMITS FOR ATTACH FITTING/BUTE DOOR CAM AT FS 280.66 IAW 57-53-01-101-001-A01. ALLOWED TO HAVE A REMAINING MATERIAL THICKNESS OF .030 CURRENT MATERIAL THICKNESS IS .055. COMPLIED WITH THE TREATMENT OF ALLOWABLE DAMAGE IAW SRM 51-12-00-001-001. TREATED RT BUTE DOOR CAMS IAW SRM 51-21-11-001-001-A01. PRIMED RT BUTE DOOR CAMS IAW SRM 51-25-16-001-001-A01.