As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND CORROSION ON STR 26R BETWEEN FUSELAGE STA 295-333. REMOVED RIVETS TO GAIN ACCESS. BLENDED AREA 6" LONG. MATERIAL REMOVED .027" AREA ALLOWED NO DAMAGE IAW SRM 53-21-03-101-007-A01. DATA SENT TO MFG FOR STRINGER SPLICE IAW REO 670-53-21-550. SPLICED IN NEW STRINGER. PRIMED, PAINTED AND INSTALLED FASTENERS.