What was found
"NR 2 AC GEN" CAUTION ILLUMINATED AFTER TAKEOFF. DIVERTED, LANDING UNEVENTFUL. FOUND FAULT 28 "NR 2 AC GCU FAIL" IN EPCU. R & R NR 2 AC GCU IAW AMM 24-21-06-000/400-801. OPS TEST GOOD. FAULT 28 DID NOT RETURN. INSPECTED NR 2 AC GEN CHIP DETECTOR FOR CONTAMINATION IAW AMM 79-34-01-200-801. NO CONTAMINATION FOUND. VISUAL CHECK OF CHIP DETECTOR INDICATIONG SYS IAW AMM 79-34-00-750-801. VISUAL CHECK GOOD. NO FAULT FOUND. RETURNED TO SERVICE.