What was found
C-CHECK -PAX DOOR INNER AFT BAY NEAR FS 347.25 HAS CORROSION IN MILLED AREA BEHIND HINGE. BLENDED OUT CORROSION BEHIND HINGE .3750 DIAMETER X .050" DEEP IAW SRM 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS IAW SRM 52-11-01-101-001-A01, SENT TO MFG ENGINEERING. PERFORMED LPI ON AFFECTED AREA, NO CRACKS OR CORROSION FOUND AT THIS TIME IAW NDTM LPI 51-20-008-230-A01. BLEND ACCEPTABLE "AS IS" IAW REO 670-52-11-507 WITHIN LIMITS. TREATED, PRIMED, PAINTED AND APPLIED CORROSION INHIBITING COMPOUND IAW REO 670-52-11-507. ALL WORK IAW HORIZON TASK CARD REO 670-52-11-507.