Service difficulty report · Smoke Detector · Cndair CL6002C10

Difficulty date
June 26, 2010
Submitted
June 30, 2010
Operation
Air carrier
Aircraft
N617QX
Make and model
Cndair CL6002C10
Aircraft serial
10130
Aircraft time
18,086 hours, 13,226 cycles
Part
Smoke Detector
Condition
False Activation
Location
Lavatory
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SMOKE AFT LAV WARNING IN FLIGHT. CIRCUIT BREAKERS PULLED IAW CHECKLIST. RETURNED TO THE FIELD. LANDING UNEVENTFUL. INSP & FOUND NO DEFECTS NOTED WITH LAV SMOKE DETECTOR. OP'S CHECKS ARE GOOD. INSP & FOUND THAT NR1 & NR2 ENGINE RECOVERY WASHES WERE PERFORMED PRIOR TO 1ST FLIGHT OF THE DAY. PERFORMED AMM TASK 72-00-00-100-801-A01 STEP 4.H. (REMOVAL OF ODOR & SOAP FUMES IN ECS SYS) & HS72-0021, 26-16-00-710-801-A01. FUMES & ODOR NO LONGER PRESENT IN ACFT. RETURNED TO SERVICE.