What was found
RFD - C CHECK - FOUND CORROSION ON STRINGER 20L BETWEEN FS485-FS501. REMOVED CORROSION FROM STR 20L AT FS485-FS501 IAW SRM 51-21-06-001-001-A01. 2 AREAS BLENDED 1ST BLEND MEASURES .5"X.5" AND .007" DEEP, 2ND BLEND WAS 1"X 1" AND .005" DEEP. ORIGINAL MATERIAL THICKNESS IS .080". BLEND FOUND TO BE WITHIN LIMITS IAW SRM 51-31-03-101-003-A01. TREATED IAW SRM 51-21-11-001-001-A01 PRIMED IAW SRM 51-25-06-001-001-A01, PAINTED IAW SRM 51-25-16-001-001-A01. APPLIED HARDCOAT TO AREA IAW SRM 51-21-11-001-001-A01.