What was found
C-CHECK - RT FLOOR SEAT TRACK HAS CORROSION NEAR FASTENER COUNTERSINK BETWEEN FS 485-581. BLENDED CORROSION ON RT FLOOR SEAT TRACK, ORIGINAL THICKNESS .110, REMOVED .038, MAX ALLOWABLE IS .035, REMAINING MATERIAL IS .072. BLEND IS OUT OF LIMITS IAW REO 670-53-00-013. REMOVED RT FLOOR SEAT TRACK FS485 - FS581 IAW AMM 53-00-49-000-801-A03. CUT BULK MATERIAL TO LENGTH. PREPARED FASTENER HOLES ON RT FLOOR SEAT TRACK IAW SRM 51-40-11-001-001-A01. INSTALLED NEW TRACK IAW AMM 53-00-49-400-801-A03.