What was found
C-CHECK - FOUND CORROSION ON FRAME AT FS 295 FROM STRINGER 27 TO 25L. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. BLENDED 2 AREAS. ONE AT THE ATTACH FLANGE BETWEEN 25L-26L MEASURED 2.0"L X 0.6"W X .002" DEEP, SECOND BLEND ON ATTACH FLANGE BETWEEN STRINGER 27-26L AND MEASURES 2.7"L X 0.6"W X .002" DEEP. ORINGINAL THICKNESS IN BOTH AREAS IS .050" REMAINING MATERIAL IN BOTH AREAS IS .048" AND FOUND TO BE WITH IN LIMITS OF SRM 53-21-06-101-002-A01. ETCHED AND ALODINED IAW SRM 51-21-11-001-001-A01. PRIMED AND PAINTED IAW 51-25-06-001-001-A01, 51-25-16-001-001-A01.