What was found
C CHECK - FOUND CORROSION ON FRAME FS 517 BETWEEN STRINGERS 25L TO 26R. BLENDED AND REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. BLENDED AREA ORIGINAL THICKNESS IS .050" DEEPEST BLEND .003" REMAINING MATERIAL IS .047" AND WITHIN LIMITS OF SRM 53-31-06-101-003-A01. TREATED AND PRIME IAW SRM 51-21-11-001-001-A01 AND 51-25-06-001-001-A01. PAINTED IAW SRM 51-25-16-001-001-A01 AND APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-21-11-001-001-A01.