What was found
RFD - C CHECK - FOUND CORROSION ON FRAME AT FS 310 FROM STRINGERS 25L - 24L. REMOVED CORROSION ON FRAME IAW SRM 51-21-06-001-001-A01. CORROSION BLENDED ON ATTACH FLANGE OF FRAME 310.0 IS 4.6"L X 0.6"W X .004"D, ORIGINAL MATERIAL THICKNESS IS .050" REMAINING MATERIAL IS .046" WITHIN LIMITS OF SRM 53-21-06-101-002-A01. TREATED AND ALODINED IAW SRM 51-21-11-001-001-A01. PRIMED IAW SRM 51-25-06-001-001-A01 AND TOP COATED IAW SRM 51-25-16-001-001-A01. APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-21-11-001-001-A01.