What was found
C CHECK - THERE IS A SMALL GOUGE IN A DENT LOCATED AT FS X87.30 AND 1.9 INCHES OTBD OF STR 32R. REMOVED PAINT AND BLENDED OUT GOUGE FROM CTR OF .022" DEEP DENT LOCATED AT FS X87.30 TO REMOVE DAMAGE. HFEC INSP BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801. NO CRACKS NOTED. HT THICKNESS CHECK IAW NDTM PART 1, 51-00-04, HIGH .032" LOW .020". MAPPED AREA FOR ENGINEERING REF RD 8/4-53-3286/3 FOR PERMANENT REPAIR.