What was found
C-CHECK - RT WING INBD FLAP IS CHAFED ON TOP SKIN PANEL AT APPROX YW60. BLENDED AREA OF CHAFE TO REMOVE DAMAGE AND FOUND IT TO BE OUT OF LIMITS IAW SRM 57-51-30-01-01. HFEC INSPECTED BLENDED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801. NO CRACKS NOTED. UT THICKNESS CHECK IAW NDTM PART 1, 51-00-04, HIGH .032, LOW .027. UT DISBOND CHECK IAW NDTM PART 1, 51-00-04, NO DISBOND NOTED. MAPPED FOR ENGINEERING. BLENDED AREA AND ADJACENT RIVET HEAD FOUND TO BE WITHIN LIMITS IAW RD 8/4-57-1405. ALODINED, PRIMED AND PAINTED IAW RD 8/4-57-1405.