What was found
C-CHECK - LT WING SLATS NR1 & 2 SHOW EVIDENCE OF CHAFING. BLENDED AREA FOUND TO BE PAINT ONLY, WITH NO MATERIAL LOSS ON LOWER T/E SKIN, WITHIN LIMITS OF SRM 57-42-01-101-001-A01. CHAFED AREA FOUND ON WING L/E (UNDER AREA OF SLAT) BLENDED AREA IAW SRM 51-12-00-001-001-A01. MEASURED CHAFE UNDER SLAT TO BE 0.6"L X 0.50"W X .002D, WITHIN LIMITS OF SRM 57-41-01-101-001-A01. TREATED PRIMED AND PAINTED AREAS IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01, 51-25-26-001-001-A02.