What was found
C-CHECK - LT SIDE, FS 280 BULKHEAD WEBBING SHOWS SIGNS OF CORROSION. BLENDED CORROSION, BLEND MEASURE .030 DEEP AND EXCEED LIMITS IAW REO 670-53-11-052. WEB IS CORRODED BEYOND LIMITS IAW REO 670-53-11-052. DRILLED OFF WEB IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01 AND REO 670-53-11-052. LOCATED FASTENER HOLES IN NEW WEB IAW REO 670-53-11-052. INSTALLED NEW WEB IAW REO 670-53-11-052. TOPCOATED AND APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-25-16-001-001-A01.