What was found
C CHECK - DURING INSP FOUND CHAFE MARK AND DAMAGED FASTENER ON DOUBLER FOR CONNECTOR ADJACENT TO AFT POTABLE WATER FILL PORT. REMOVED DAMAGED FASTENER IAW SRM 51-42-06-001-001-A01. BLENDED CHAFE MARK, BLEND IS WITHIN LIMITS IAW SRM 53-00-01-101-001-A01. ETCHED, ALODINED, PRIMED AND INSTALLED NEW FASTENERS IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01, 51-42-06-001-001-A01. TOPCOATED IAW SRM 51-25-16-001-001-A01. APPLIED CORROSION INHIBITING COMPOUND TO AFFECTED AREAS IAW SRM 51-21-11-001-001-A01. ALL BLENDS DONE IAW SRM 51-12-00-001-001-A01.