What was found
C-CHECK - FRAME AT STA 301.000 LOWER ATTACH FLANGES BETWEEN STR 31L AND 31R HAVE MINOR CORROSION. REMOVED CORROSION FROM FLANGES IAW SRM 51-21-00. REMOVED RIVETS TO FOM IAW SRM 51-40-07. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .044" REF HORIZON NTM 4.2.0-1. REMAINING MATERIAL OUT OF LIMITS IAW Q400 SRM 53-30-15. REMOVED FRAME FLANGE BETWEEN STR 33 AND 32R IAW Q400 RD 8/4-53-017. CONFIRMED AFFECTED AREA IS CRACK FREE REF RD 8/4-53-017 AND Q400 NTM 51-00-01-250-801. FABRICATED FRAME ANGLE SPLICE IAW Q400 RD 8/4-53-017. INSTALLED FRAME FLANGE REPAIR ANGLE IAW Q400 RD 8/4-53-017. CONFIRMED AFFECTED AREA IS CRACK FREE REF HORIZON NTM 51-00-01-250-801. NO CORRISON FOUND AFTER CLEANING. APPLIED ALODINE AND PRIMER IAW RD 8/4-53-017, APPLIED TOP COAT IAW RD 8/4-53-017. APPLIED CORROSION PREVENTATIVE COMPOUND TO REPAIR AREA IAW AMM 51-25-01-390-801.