What was found
C-CHECK - FRAME AT STA 94.800 LOWER ATTACH FLANGE BETWEEN STR 31 AND 32R HAS MINOR CORROSION. REMOVED CORROSION REF SRM 51-21-00, REMOVED 5 RIVETS TO FOM REF 51-40-07. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .039 REF HORIZON NTM 4.2.0-1. REMOVED FRAME FLANGE IAW RD 8/4-53-017. FABRICATED FRAME FLANGE IAW RD 8/4-53-017AND SRM 51-40-07. VERIFIED CRACK FREE CONDITION IAW RD 8/4-53-017. TREAT AND PRIME IAW RD 8/4-53-017. INSTALLED FABRICATED FLANGE AND TOPCOATED IAW RD 8/4-53-017.