What was found
COE -C5 CHECK - INTERIOR FRAME FLANGE AT STA 32.40 BETWEEN STRINGERS 31R AFT SIDE HAS CORROSION. REMOVED CORROSION FROM FLANGES AT STA 32.40 STR 32-31R AND STR 31-30R IAW SRM 51-21-00. MEASURED AFFECTED AREA, MIN MATERIAL REMAINING .035" REF NTM 51-00-02-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15. REMOVED DAMAGED FLANGES FROM FRAME AT STA 32.40 STR 32-31R AND STR 31-30R IAW SRM 53-10-15, REPAIR 01. CONFIRMED CRACK FREE CONDITION OF AFFECTED AREA REF NTM 51-00-01-250-801. FABRICATED NEW FLANGES FOR FRAME IAW SRM 53-10-15 REPAIR-01. APPLIED ALODINED, PRIMED IAW SRM 51-21-10 AND 51-25-10. INSTALLED REPAIR FLANGES IAW SRM 53-10-15 REPAIR -01 AND 51-42-05. PRIMED AND PAINTED IAW SRM 53-10-15-02-01.