What was found
RFD - C4 CHECK - DURING INSP FOUND CRACK IN WEB FLOOR UNDER ADG STOW PUMP. STOW PUMP IAW AMM 24-23-19-000-801-A01. REMOVED EXISTING DOUBLER OF ADG STOW PUMP IAW REO 670-53-11-509. TRIMMED CRACK AREA IAW REO 670-53-11-509. PERFORMED LPI ON CUT OUT, NO CRACKS NOTED AT THIS TIME IAW NDTM LPI 51-20-008-230-A01 AND REO 670-53-11-509. FABRICATED RT SIDE TYPE II DOUBLER AND CLEAT. TREATED, PRIMED AND PAINTED IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. INSTALLED REPAIR DOUBLER AND CLEAT IAW REO 670-53-11-509. INSTALLED PUMP IAW AMM 24-23-19-400-801.