As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INTERIOR FRAME FLANGE AT STATION X196.000 AT STRINGER 13R AFT SIDE HAS CORROSION. REMOVED RIVET FOR INSPECTION REMOVED CORROSION. MATERIAL REMOVED IS OUT OF LIMITS. FABRICATED REPAIR ANGLE FROM 0.63" 2024 T-3. INSTALLED REPAIR IAW SRM 53-10-15. PRIMED AND PAINTED AS REQUIRED.