What was found
C4 CHECK - DURING INSP FOUND CORROSION AT FRAME FS 265 ON THE FRAME STIFFENING ANGLE ATTACH FLANGE BETWEEN STR 26L AND 26R AT THE MIDDLE OF THE STIFFENER. BLENDED CORROSION 4"L X 1.6"W X .001"D IAW SRM 51-21-06-001-001-A01, ORIGINAL THICKNESS .050", REMOVED .001", REMAINING THICKNESS .049" FOUND TO BE WITHIN LIMITS IAW SRM 53-11-06-102-008-A01. PERFORMED ECI ON BLENDED AREA, NO CRACKS OR CORROSION FOUND AT THIS TIME IAW NDTM ECI 51-20-006-250-A01. TREATED, PRIMED, PAINTED AND APPLIED CORROSION PREVENTATIVE COMPOUND IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01, 51-25-16-001-001-A01 AND 51-21-11-001-001-A01.