What was found
C3 CHECK - AVIONICS BAY DOOR FWD STRUCTURE ATTACHMENT ANGLE AT STR 26L IS CORRODED. BLENDED OUT CORROSION IAW SRM 51-21-06-001-001-A01, REMOVED .003" OF MATERIAL, REMAINING MATERIAL IS .060" WITHIN LIMITS IAW SRM 53-21-23-001-003-A01. TREATED, PRIMED AND PAINTED WORKED AREA IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. TREATED, PRIMED AND PAINTED ATTACH ANGLE IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. INSTALLED ATTACHMENT ANGLE IAW SRM 51-42-06-001-001-A01 AND 51-42-20-001-001-A01. APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-21-11-001-001-A01.