What was found
C2 CHECK - INTERNAL FUSELAGE FRAME AT STA X6.00 BETWEEN STR 24P AND 25P HAS CORROSION. CLEANED AND REMOVED SURFACE CORROSION IAW SRM 51-21-00. MEASURED AFFECTED AREA, MIN THICKNESS REMAINING .048" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION OF AFFECTED AREA, REF RD 8/4-53-2344. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. TREATED, PRIMED AND PAINTED IAW SRM 51-21-10, 51-25-10 AND 51-25-15. APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-25-00.