What was found
C2 CHECK - INTERIOR FUSELAGE FRAME LOWER FLANGE AT STA X281.000 HAS CORROSION BETWEEN STR 31S AND 32S. REMOVED RIVETS COMMON TO EXTERNAL SKIN FOR ACCESS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW RD 8/4-53-2344. MEASURED AFFECTED AREA MIN THICKNESS REMAINING .046" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION REF RD 8/4-53-2344. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS REF SRM 51-42-05. TREATED AND PAINTED REF SRM 51-25-05, 51-21-10 AND 51-20-00.