What was found
C2 CHECK - LT INBD SEAT RAIL NR8 HAS AREAS OF CORROSION BETWEEN STA X635.00 AND X654.00. REMOVED CORROSION. MINIMUM THICKNESS FOUND .4462". FOUND TO BE WITHIN LIMITS. DONE IAW RD 8/4-53-884. ALODINE DONE IAW SRM 51-21-10-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C2 CHECK - LT INBD SEAT RAIL NR8 HAS AREAS OF CORROSION BETWEEN STA X635.00 AND X654.00. REMOVED CORROSION. MINIMUM THICKNESS FOUND .4462". FOUND TO BE WITHIN LIMITS. DONE IAW RD 8/4-53-884. ALODINE DONE IAW SRM 51-21-10-02-01.